- Designed for ensuring Grade D breathing air when equipped with available CO/O2 monitor
- Two-stage prefilter/coalescer removes oils, water and solid particles
- 100 CFM capacity with 5 outlets for connection to supplied-air respirators
- Adsorber removes unpleasant odor and taste
- Compatible with a variety of ENMET carbon monoxide and oxygen monitors
- System is provided with wall-mount brackets
Inlet Pressure: Maximum 230 psi
Manifold Pressure: Maximum 100 psi, system supplied with regulator and 160 psi gauge
Pressure Relief Valve: Factory set to open at 100 psi and limits manifold pressure
Total Air Capacity: Maximum 100 CFM
Outlet Connection: Supplied with 5 quick-disconnects (Hansen series compatible) for connecting respirators. A sixth quick-disconnect can be used for connecting a CO/O2 monitor or additional respirator
Inlet Port: 3/4 inch NPT, female
Prefilter/Coalescer: Removes oil, water, and solid particles
Prefilter/Coalescer Drain: For periodically removing collected fluids in the prefilter bowl
Pressure Drop Indicator: Indicates the condition of the prefilter/coalescer element and when to change it
Adsorber: Removes unpleasant odor and taste from the air system
Adsorber Drain: For periodically removing collected fluids in the adsorber bowl
Size: 20.6 W x 17.2 H x 6.2 D inches (52.4 W x 43.8 H x 15.8 D cm)
Weight: 30 lbs. (13.6 kg)
Options:
- AFS-100 can be supplied in a portable cradle, with or without CO/O2 monitor
- AFS-100 can be supplied with Schrader fittings