PRODUCT HIGHLIGHTS
- Designed for ensuring Grade D breathing air when equipped with available CO/O2 monitor
- Two-stage prefilter/coalescer removes oils, water and solid particles
- 50 CFM capacity with 4 outlets for connection to supplied-air respirators
- Adsorber removes unpleasant odor and taste
- Compatible with a variety of ENMET carbon monoxide and oxygen monitors
- System is provided with wall-mount brackets
Inlet Pressure: Maximum 150 psi
Manifold Pressure: Maximum 100 psi, system supplied with regulator and 160 psi gauge
Pressure Relief Valve: Factory set to open at 100 psi and limits manifold pressure
Total Air Capacity: Maximum 50 CFM
Outlet Connection: Supplied with 4 quick-disconnects (Hansen series 1000 compatible) for connecting respirators. A fifth quick-disconnect can be used for connecting a CO/O2 monitor or additional respirator
Inlet Port: 1/2 inch NPT, female
Prefilter/Coalescer: Removes oil, water, and solid particles
Prefilter/Coalescer Drain: For periodically removing collected fluids in the prefilter bowl
Pressure Drop Indicator: Indicates the condition of the prefilter/coalescer element and when to change it
Adsorber: Removes unpleasant odor and taste from the air system
Adsorber Drain: For periodically removing collected fluids in the adsorber bowl
Size: 11.5 W x 14.6 H x 5 D inches (29.2 W x 37.1 H x 12.6 D cm)
Weight: 10 lbs. (4.5 kg)
Optional Plate: Painted steel construction 21 W x 17 H (53.3 W x 43.2 H cm)
Weight: 13 Lbs. (5.9 kg)
Options:
- AFS-50 can be supplied on a wall-mount plate, with or without a CO/O2 monitor.
- AFS-50 can be supplied with Schrader fittings